Probes,
Condensaatvoorafscheiding, Filters, Koelers en Pompen
Probes
Model Probes 222 series
Brochure
Non hazardous area
Hazardous area
dust concentration
filter Type
heated
selfregulated
heated
regulated
unheated
zone 1
zone 2
process
temperature
max.
max. allowed operating pressure 6
bar / max. probe inlet temperature
200 °C
up to 2g/m³
downstream
filter
GAS 222.15
GAS 222.20
GAS 222.10
GAS 222.20 ATEX
GAS 222.20 ATEX 2
1700 °C
GAS 222.17
GAS 222.11
GAS 222.21
steam
heated
GAS 222.20DH
GAS 222.21 ATEX
GAS 222.21 ATEX 2
> 2 g/m³
in-situ filter
GAS 222.31
GAS 222.30
GAS 222.31 ATEX
GAS 222.31 ATEX 2
1000 °C
> 2 g/m³
In-situ and downstream
filter
GAS 222.21
GAS 222.21 ATEX
GAS 222.21 ATEX 2
> 2 g/m³
without tools replaceable
In-situ filter
GAS 222.35
GAS 222.35U
GAS 222.35 ATEX
GAS 222.35 ATEX 2
600 °C
max. allowed operating pressure 6
bar / max. probe inlet temperature
120°C
> 2 g/m³
In-situ filter
ECO-01
260°C
max. allowed operating pressure 16
bar / max. probe inlet temperature
600 °C
> 2 g/m³
In-situ filter
APO
600°C
Condensaat voorafscheiding en afvoer
Voorkoelers
Brochure
Condensaat
afvoervaatjes
Brochure
Condensaatpompen
Brochure
Filters
Model AG-PV-30
•
Bühler Unique-QC bracket
• material of filterhousing: PVDF,Glass
• different filter-dimensions
• different element-materials and retention rates
• small death volume
• additional port for bypass or moisture detector
Brochure
Model AGF-T-30
• material of filterhousing: PTFE,Glass
• sintered PTFE elements
• highly corrosion resistant
• different filter dimensions
Brochure
Model AGF-VA-23
• Bühler Unique-QC
bracket
• material of filterhousing: SS
• suitable for use in high pressure applications, inflammable gases
and trace measurements
Brochure
Model AGF-FE
• front
panel mounting
• easy installation
• quick change of filter-element
Brochure
Voor ander type filters en modellen, neemt u a.u.b.
contact met ons op
Koelers
Model PKE 4
•
peltier Cooler
• cooling capacity 70 Kj/h
• heat exchanger made out of SS, glass or PVDF
• dew point stability 0,1 °C
• display for cooling block temperature and alarm
reading
• version for high ambient temperatures above 45° C
available
Brochure
Model EGK 1-2
• compressor cooler
• cooling capacity 320 Kj/h
• 1 or 2 gas streams
• heat exchanger made out of SS, glass or PVDF
• display showing the cooling block temperature and
alarms
• ambient temperature max 50 °C
Brochure
Model EKG 2-Ex
• compressor cooler
• cooling capacity 615 Kj/h
• 1 or 2 gas streams
• heat exchanger made out of SS, glass or PVDF
• status display
• ambient temperature max 45°C
• Atex certificated
Brochure
Model EGK-4S
• compressor Cooler
• cooling capacity 800 Kj/h
• up to 4 separate gas streams
• heat exchanger made out of SS, glass or PVDF
• ambient temperature max 50 °C
Brochure
Model EGK 10
• compressor cooler
• cooling capacity 1450 kj/h
• heat exchanger only in SS avalaible
• flow rate up to 3900 l/h
• display showing the cooling block temperature and alarms
• ambient temperature max 50 °